Publication 900-UM004D-EN-E - July 2010
Bulletin 900 Communications Procedures 900-TCx (CompoWay/F) 2-17
Operating status
Related information
Response Code
Normal Completion
Error Occurred
Echoback Test
This service carries out the echoback test
Service Request PDU
Table 2.21
Run Status Description
00 Control is being carried out (error has not occurred in setup area 0, and the
controller is running).
01 Control is not being carried out (state other than above).
Table 2.22
Response Code Name Description
0000 Normal completion No errors were found.
Table 2.23
Response Code Name Description
1001 Command too long The command is too long.
2203 Operation error EEPROM error
7654 3210
0
Heater overcurrent (CT1)
Heater current hold (CT1)
AD converter error
Heater overcurrent (CT2)
Heater current hold (CT2)
Display range exceeded
Input error
Bit position
MRC SRC Test Data
0081
2 2 0 to 200