Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 71
FANUC CNC Configuration Chapter 3
P0001 (OP Panel Path 1)
This application program manages the operator
panel and MDI panel I/O interface. The
Machine mode push buttons, indicator lights,
and feed rate override signals are controlled from
this program routine.
P0005 (Machine Sequence)
This application program manages the
sequencing involved in a machine tool
application. This, along with other programs
(provided by the OEM) specific to the machine
application will control machine I/O, and/or
control overall machine functionality.
Edit this file as necessary to control the machine
to meet the performance specifications required
for the application. To maintain code modularity,
add additional files on a function by function
basis.
Kommentare zu diesen Handbüchern