Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 255
Appendix
C
Add Other Devices to the Equipment Status Faceplate
In this appendix you add devices that do not have pre-configured faceplates, such as a discrete device (solenoid or
valve).
Add Devices to the Equipment Status Faceplate
1. Go to the Object Explorer dialog box and select which Row_Group you wish to display the
Non-preconfigured Device in.
2. Find the DeviceName_String_x object for that row.
3. Double-click DeviceName_String_x
object to open the String Display
Properties and click the Connections
tab.