Rockwell-automation 57C422B 2 Axis Servo Module Bedienungsanleitung Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 122
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
3-4
2-Axis Servo Module M/N 57C422B
.
Use twisted pair cabling, connected as shown in
figure 3.3, for the cabling between the power
supply and the terminal strip. If you use cabling
with less than 2 twists/inch, it should be shielded.
Note that the shield should only be connected at
one end.
For best results, the power supply voltage should
be adjusted to provide 5 volts at the furthest
encoder.
Step 7. If your application requires them, mount the home
L/S, positive overtravel L/S, and negative
overtravel L/S on your machine. Overtravel L/S
should be normally closed devices. Fasten the
field wires from the limit switches to the terminal
strip. Typical field connections are shown in figure
3.4.
Figure 3.3 – Typical Encoder Power Supply Connection