Rockwell-automation 1760-xxxx Pico GFX-70 Controllers User Manual Bedienungsanleitung Seite 122

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 400
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 121
Publication 1760-UM002B-EN-P - March 2005
4-12 Wiring with Pico GFX-70
The options for setting output and marker relays are listed with the description
of each coil function.
The function block coil functions and parameters are listed with the
description of each function block type.
Markers, Analog Operands
Specific markers are available for actively addressing values or inputs/outputs.
When using the COM communication mode, you can make the following data
accesses on the slave. Note the REMOTE MARKER SETTING in the
following table.
Table 4.4 Markers
Markers
Analog operand
Pico GFX-70
display
Number Value
range
Access type
r = Read
w = Write
Marker 32-bit MD 01
96 32-bit r, w
Marker 16-bit MW 01
96 16-bit r, w
Marker 8-bit MB 01
96 8-bit r, w
Marker 1-bit M 0
96 1-bit r, w
Analog inputs basic
unit
IA X X=01
04 10-bit r
Analog output QA X X=01 10-bit r, w
Seitenansicht 121
1 2 ... 117 118 119 120 121 122 123 124 125 126 127 ... 399 400

Kommentare zu diesen Handbüchern