Seitenansicht 117
C-10
DeviceNet Adapter for use with DPI AC Drives
Services
10 Get Minimum
Value
13
11 Get Maximum
Value
13
12 Get Default Value
13
13 Get Scaling
Multiplier
UINT
3
14 Get Scaling Divisor UINT
3
15 Get Scaling Base UINT
3
16 Get Scaling Offset UINT
3
17 Get Multiplier Link UINT
3
18 Get Divisor Link UINT
3
19 Get Base Link UINT
3
20 Get Offset Link UINT
3
21 Get Decimal
Precision
USINT
3
1
Access rule is defined in bit 4 of instance attribute 4. 0 = Get/Set, 1 = Get.
2
Specified in descriptor, data type, and data size.
3
Value varies based on parameter instance.
4
Refer to the DeviceNet specification for a description of the connection path.
Attribute
ID
Access
Rule Name
Data
Type Description
Service
Code
Implemented for:
Service NameClass Instance
0x01 No Yes Get_Attribute_All
0x05 Yes No Reset
0x0E Yes Yes Get_Attribute_Single
0x10 No Yes Set_Attribute_Single
0x15 Yes No Restore_Request
0x16 Yes No Save_Request
0x4B No Yes Get_Enum_String