Publication GMLC-5.2 - November 1999
Motion Controller Functions 633
AxisLink Group Output
Use the AxisLink_group_output function to directly specify AxisLink
output groups in an expression.
You define and select output groups using the Tag Explorer (under
AxisLink I/O Output Group) and the Tag Window. It is not necessary to
use this function to specify them directly.
Syntax:
AxisLink_group_output[address, total signals in group, optional
mask]
Flex I/O Group Output
Use the Flex_IO_group_output function to directly specify Flex I/O
discrete output groups in an expression directly. This function is available
only if your motion controller is running i
CODE
version 3.0 or later (as
selected in the Configure Control Options dialog box).
Optional Mask An integer representing the sum of the binary value of each group
input bit whose signal is read, excluding—or masking—the binary
value of every group input bit whose signal is not read. (See
Optional
Masks
in the
Group
Input
section.)
Argument Description
Address The address, or signal number (from 0 to 15), of the first signal from
which output is read.
Total Signals in
Group
The total number of consecutive signals (from 1 to 16) comprising the
group, including any masked (or omitted) signals.
Optional Mask An integer representing the sum of the binary value of each group
input bit whose signal is read, excluding—or masking—the binary
value of every group input bit whose signal is not read. (See
Optional
Masks
in the
Group
Input
section.)
Argument Description