Publication GMLC-5.2 - November 1999
Motion Controller Functions 613
Insert a value or expression equal to the desired address. The argument is
evaluated as an integer (floating point values are truncated) and must have
a value from 0 to 11 inclusive. The Input function evaluates as 1 (true) if
the input is ON, and 0 (false) if it is OFF.
Miscellaneous Inputs
Use the Miscellaneous Input function to include the state of the non-axis-
specific, dedicated input on the motion controller in an expression.
Syntax:
Miscellaneous_input[input number]
Insert a value or expression equal to the desired input number from the
table below.
The argument is evaluated as an integer (floating point values are
truncated) and must have a value from 0 to 9 inclusive.
Input
Number Description
0 Initialization Input
1 Application Lock
2 Data Lock (Compact, Integrated, and Basic only)
3Plug Lock
4 External Enable 1394 (1394 only)
5 Hard Fault 1394 (1394 only)
6 Watchdog OK 1394 (1394 only)
7 Dualport Initialization 1394 (1394 only)
8DSP Bus Grant
9 DH485 Switch