OCI Data ItemsA–16
Publication 8520-6.6. - August 1999
Control TypeReqDual
Proc.
Units
Dependency
UnitsArray IndicesNum
Indices
OCI/9/PCData TypeDescriptionItem (Name)
364
RACK_1394_SYSTEM_MODULE_HW_REVI
SION
Revision number associated with each rack of
1394 drives
UINT[ ] 9/PC 1 MAX_1394_SE
RIAL_RACKS
No R All Controls
365
RACK_1394_SERCOS_ADDRESS Configured address associated with each rack
of 1394 drives
UINT[ ] 9/PC 1 MAX_1394_SE
RIAL_RACKS
No R All controls
366
RACK_1394_BOARD_NUMBER Physical connector number for a 1394 rack to
the CNC
UINT 9/PC 1 MAX_1394_SE
RIAL_RACKS
No R All Controls
367
RACK_1394_AXIS_MODULE_ERRORS Error codes for the axis modules in one 1394
rack
UINT[ ] 9/PC 1 MAX_1394_SE
RIAL_RACKS
No R All Controls
348
ROLLOVER_AXIS_LOGICAL_BIT_PATTERN Bit pattern of axes configured as rollover UDINT Both Yes R All Controls
348
ROTARY_AXIS_LOGICAL_BIT_PATTERN Bit pattern of axes configured as rotary UDINT Both Yes R All Controls
22
SERVO_NAME Servo Names in AMPed Order SINT [ ] AMP Both 1 Num Servos No R All Controls
338
VIRTUAL_AXIS _ALLOWED Value is true if system supports virtual axis INT [ ] Both Yes R All Controls
323
VIRTUAL_FORMATS Num digits to the right of the decimal point for
virtual/cylindrical axes
INT [ ] Both 1 Num Virtual Names Yes R All Controls
322
VIRTUAL_NAMES Axis name used for virual C and cylindrical fea
tures
INT [ ] Both 1 Num Virtual Names Yes R All Controls
v
Servo Parameters
199
AXIS_SKEW_AMOUNT Amount of Axis Skew LREAL [ ] Both 1 Num Skew Slaves Inch/
Metric/
Degrees
Active Units Yes R All Controls
134
DISTANCE_TO_MARKER Distance To Marker LREAL [ ] Both 1 NUM_SER
VOS_PLUS_SPIN
DLES
Inch/Met
ric/De
grees
ACTIVE_UNITS Yes R All Controls
130
FEED_FORWARD_PERCENT Feed Forward Percentage LREAL [ ] Both 1 NUM_SER
VOS_PLUS_SPIN
DLES
Yes R/W All Controls
124
FOLLOWING_ERROR Following Error LREAL [ ] Both 1 NUM_SER
VOS_PLUS_SPIN
DLES
Inch/Met
ric/De
grees
ACTIVE_UNITS Yes R All Controls
290
HOME_CALIBRATION_AMOUNT Home calibration amount - Online AMP LREAL [ ]
Both
1 NUM_PROG_AXE
S_PLUS_SKEWS
LAVES
Inch/Met
ric/De
grees
ACTIVE_UNITS No R/W All Controls
136
MARKER_STATUS Marker (Not) Found UINT bit pattern Both 0 Num Servos Yes R All Controls
128
MAX_NEGATIVE_TORQUE Maximum % Rated Torque (-) LREAL [ ] Both 1 NUM_SER
VOS_PLUS_SPIN
DLES
Yes R/W All Controls
127
MAX_POSITIVE_TORQUE Maximum % Rated Torque (+) LREAL [ ] Both 1 NUM_SER
VOS_PLUS_SPIN
DLES
Yes R/W All Controls
Kommentare zu diesen Handbüchern