48 Rockwell Automation Publication 842E-UM001A-EN-P May 2012
Chapter 7 Diagnostics and troubleshooting
16 Position
error
Single-turn position error (error in the
sensor)
0 1 YES A
2 17 Position
error
Multi-turn position error
(synchronization MA single)
0 1 YES A
18 Position
error
Multi-turn position error
(synchronization quad single)
0 1 YES A
19 Position
error
Multi-turn position error (internal
interface)
0 1 YES A
20 Position
error
Multi-turn position error (FRAM) Always
0
–NO A
21
…
23 Reserved Reserved Always
0
NO –
24 Position or
memory
error
Memory error (EEPROM checksum) 0 1 YES A
3 25 Memory
error
Memory error (EEPROM IRQ) 0 1 YES A
26 Startup error Error on start-up 0 1 YES A
27 Diagnostic
error
Error during self-test 0 1 YES A
28
…
29 Reserved Reserved
30 Slave sign of
life
LifeSign; active if attribute 13 is set 0 1 YES –
31 Reserved Reserved Always
0
NO –
Fault
header
[byte] Bit Error Description
FALSE
(0)
TRUE
(1) Supported
Warning/
alarm