5–38 Configuring Your Reader
Publication 2755-6.9
Scanner Setup Commands
Scanner Type. You determine the type of reader you are using.
Entering the <Zp> command will save the current setting for
Scanner Type to NOVRAM.
Command Parameter Format Example
Scanner Type
0 = Standard
KP <KPdensity> Do not change the reader type.
1 = High Density
KP <KPdensity> Do not change the reader type.
Scans per Second. The scan occurs in 10 millisecond increments.
You can use any number between 30 and 55. The default is 50.
Parameter Format Example
KE <KEspeed>
To set the reader to 400 scans per
second, press [<KE40>].
Auto Gain Control. Gain adjustment can be any number from 10
to 255. The default is 45.
Before saving any changes to Gain Adjustment, first record the
optimized factory setting for future reference. Press
[<KU?>] to
read factory settings.
Command Parameter Format Example
AGC Sampling
0 = Disabled
<KDgain adjustment,AGC
To set the gain threshold to 40 and the
1 = Leading Edge
KD
<KDgain adjustment,AGC
sampling,tracking>
AGC status to Leading Edge, press
[<KD40 1 0>]
2 = Continuous
[
<KD
40
,
1
,
0
>
]
.
Bad Bar Code Message. You can use any ASCII string up to 7
characters. The default is Bad Code.
Command Parameter Format Example
Status
0 = Disabled
KM <KMstatus,message>
To change the message to “FAULTY”,
[<KM1 FAULTY>]
1 = Enabled
KM <KMstatus,message>
press [<KM1,FAULTY>].
No Bar Code Message. You can use any ASCII string up to 7
characters. The default is No Label.
Command Parameter Format Example
Status
0 = Disabled
KN <KNstatus,message>
To change the message to NO LABEL,
[<KN1 NOCODE>]
1 = Enabled
KN <KNstatus,message>
press [<KN1,NOCODE>].
No Object Message. You can use any ASCII string up to 7
characters. The default is Missing.
Command Parameter Format Example
Status
0 = Disabled
KO <KOstatus,message>
To change the message to “VACANT”,
[<K01 VACANT>]
1 = Enabled
KO <KOstatus,message>
press [<K01,VACANT>].