5–37Configuring Your Reader
Publication 2755-6.9
• Beeper
Command Parameter Format Example
Beeper Status
0 = On Good
1 = On No Read
Beeper Volume
0 = Off
To set the beeper for On No Read and
1 = Level 1
Ku <Kustatus,volume> set the beeper volume to Off, press
2 = Level 2
<Ku
,
>
.
3 = Level 3
4 = Level 4
5 = Level 5
• Laser On/Off
Command Parameter Format Example
Status
0 = Disabled
KC <KCstatus>
To enable Laser On/Off, press
1 = Enabled
KC <KCstatus>
[<KC1>].
• Serial Verification
Command Parameter Format Example
Serial Command Echo Status
0 = Disabled
1 = Enabled
Serial Command Beep Status
<KSserial command
To enable Serial Command Echo Status,
0 = Disabled
KS
status,serial command
To enable Serial Command Echo Status,
Beep status, and Hex Output, press
1 = Enabled
KS
beep status,control/hex
Beep status, and Hex Output, press
[<KS1,1,1>].
Control/hex Output
output>
0 = Control
1 = Hex
• User Output Status Request. Allows you to return the status of
each command in the group.
Parameter Format
KX <KX?>
• Partial Label Output. Allows you to transmit a portion of the
label to the host.
Command Parameter Format Example
Status
0 = Disabled
1 = Enabled
To enable Partial Label Output starting
Start Position
KY
<KYstatus,start
To enable Partial Label Output starting
at character 4 and ending at character 8
KY
position,length>
at character 4 and ending at character 8
1 to 63. 1 is the default.
of the string, press
<KY
,
,
>
.
Length
1 to 63. 63 is the default.