Publication 2098-PM001E-EN-P — July 2002
Referencing the Motion Library 2-39
long JogStop(void);
Stops the jog motion using the programmed deceleration value.
Returns 0 if successful, or -1 on an error.
Jog Status
long JogAtSpeed(void);
Determines if a jog is at the programmed speed.
Returns non-zero if jog is at speed.
long JogGetMode(void);
Returns one of the following jog mode values:
0 = Stop
1 = Forward
2 = Reverse
long JogGetState(void);
Returns one of the following jog state values:
0 = Locked
1 = Seeking
Ultraware displays one of the following status displays in response to
the function.
Display Description
Locked Jog is at the specified speed in the forward or reverse direction, or
is at the zero speed when specified (i.e., current velocity equals
program velocity).
Seeking Motor is accelerating or decelerating to a specified jog speed.