Rockwell-automation 1336T Function Block Prog. Manual, Series A/B Bedienungsanleitung Seite 123

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 180
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 122
5–7Block Transfer Services
1336 FORCE — 5.9 August 1995
The Write Task Name message is used to write a task name to a data
buffer. The task name may contain up to 16 characters.
PLC Block Transfer Instruction Data
BTW Instruction Length: 11 Words
BTR Instruction Length: 3 Words
Message Structure
0
Header
Word 1
Header
Word 1
0
3846 –– Message OK
0
Header
Word 2
Data
Word 3
Header
Word 2
Header
Word 3
Data
Word 4
0
PLC Request –– Block Transfer Write
Drive Response –– Block Transfer Read
–28922
Data
Word 11
Char 2 Char 1
Char 16 Char 15
–28922 –– Message Error
Message Operation
The User ID Text String allows you to read or write 16 characters of
text from or to a data buffer.
Example
This example shows the Write Task Name operation in ASCII
representation:
10
N10:10
23456789
N10:90
BTW
Data File
BTR
Data File
Data Format
\00\00 rd
\00\00
0
0
\0F\06
\0F\06
vi e 1#
Application Status
Services:
Write Task Name
Seitenansicht 122
1 2 ... 118 119 120 121 122 123 124 125 126 127 128 ... 179 180