7-4 Communicating with Devices on a ControlNet Link
Configuring Distributed I/O
The DriveLogix5730 controller supports distributed I/O over a ControlNet
link. Configuring I/O in a remote chassis is similar to configuring local I/O.
You create the remote communication module and distributed I/O modules
on the local ControlNet daughtercard.
To communicate with distributed I/O modules, you add a remote adapter
and I/O modules to the I/O Configuration folder of the controller.
1. Add the remote adapter to the
ControlNet daughtercard of the
controller.
2. Add the I/O modules to the remote
adapter.
ahw0924.tif
To Add Distributed I/O Build the I/O Configuration in this Order
Seitenansicht 143