Publication 2092-RM001A-EN-P — March 2005
Command Reference 2-35
[Pr – 5.12] Analog Output CH1 Selection
[Pr – 5.13] Analog Output CH2 Selection
[Pr – 5.14] Analog Output CH1 Scale
[Pr – 5.15] Analog Output CH2 Scale
Ultraware Name: Analog Output 1: Signal
Range: Refer to Monitor Variables on page A-3 (except 0x0F)
Default: 0x00
Operating Mode: All
Ultraware Name: Analog Output 2: Signal
Range: Refer to Monitor Variables on page A-3 (except 0x0F).
Default: 0x00
Operating Mode: All
Ultraware Name: Analog Output 1: Scale
Range: 1 to 5000
Units: Units depends on the channel selection.
Refer to Monitor Variables on page A-3.
Default: 500
Operating Mode: All
Ultraware Name: Analog Output 2: Scale
Range: 1 to 5000
Units: Units depends on the channel selection.
Refer to Monitor Variables on page A-3.
Default: 500
Operating Mode: All