  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 40
Troubleshooting 9–3
Table 9.B (continued)
160 Drive1 Fault Codes
1
Refer to the
160 User Manual
for the most current fault code information.
Table 9.C
RS1 Fault Codes
RS1/DF1 Error Codes
The following error codes could be returned over DF1 (with the
Message Command) when accessing the RS1 Module.
Table 9.D
Error Codes
Fault Code Fault Indication Description Corrective Action
40 Phase W Fault Phase to ground fault detected between drive
and motor phase W.
Check wiring between drive and motor. Check motor
for grounded phase.
41 UV Short Fault Excessive current has been detected between
these two drive output terminals.
Check the motor and external wiring to the drive
output terminals for a shorted condition.
42 UW Short Fault Excessive current has been detected between
these two drive output terminals.
Check the motor and external wiring to the drive
output terminals for a shorted condition.
43 VW Short Fault Excessive current has been detected between
these two drive output terminals.
Check the motor and external wiring to the drive
output terminals for a shorted condition.
48 Reprogramming Fault Occurs when reset defaults is performed. Clear fault.
49 Zero Overload Fault Occurs when load requires excessive current at
zero hertz.
Reduce motor load and/or motor dwell time at zero
hertz.
Fault Code Fault Indication Description Corrective Action
51 RS1 Module EPROM Fault Module EPROM has invalid data. Reset to factory defaults P128 - [Reset RS1].
52 RS1 Lost I/O Connection Application timed out. Check master for correct operation (i.e., powered up,
run mode, etc.).
55 Force Fault P127 - [Force Fault] was set to “1. Clear fault.
Message STS EXT STS Problem Problem
All Messages 10h N/A Illegal command or format. The RS1 does not support this command.
F0h 06h Address does not point to anything usable. The address does not exist, or does not point to anything usable
by this command.
F0h 0Ah Transaction size plus word address is too large. Trying to read/write multiple parameters with one command.
Writing one parameter at a time or reading past end of last
parameter is only supported.
F0h 12h Invalid parameter or data. Data out of range.
F0h 1Eh Data table element protection violation. Write to Read Only parameter.
F0h 1Fh Temporary internal problem. Unable to execute due to temporary internal conditions –
Parameter Read Only when drive is running.