Seite 1 - Serial Converter

User ManualSmartSelf-poweredSerial Converter1203-SSS (Series B)FRN 3.xxx

Seite 2 - Important User Information

1-2 Getting StartedFeatures of the serial converter include the following:• Three status indicators (LEDs) report the operating status of themodule.•

Seite 3 - Summary of Changes

Getting Started 1-3Equipment Shipped with the Serial ConverterWhen you unpack the serial converter, verify that the package includes:User-Supplied Equ

Seite 4

1-4 Getting StartedPlease read the following safety precautions carefully.Safety Precautions!ATTENTION: Risk of injury or equipment damage exists. Onl

Seite 5 - Table of Contents

Getting Started 1-5This section is designed to help experienced users start using the serialconverter. If you are unsure how to complete a step, refer

Seite 6 - Appendix C Flash Updates

1-6 Getting StartedFigure 1.4 Status Indicators on the Serial ConverterThe serial converter reports its status using status indicators (Figure 1.4).

Seite 7 - About This Manual

Chapter 2Installing the Serial ConverterChapter 2 provides instructions for installing and removing the serialconverter.The following cables are all y

Seite 8 - Rockwell Automation Support

2-2 Installing the Serial Converter1. Connect the serial converter to the product using the 1202-C10 cable.Figure 2.2 Connecting a 1202-C10 Cable to

Seite 9 - Getting Started

Chapter 3Configuring the Serial ConverterChapter 3 provides information about configuring the serial converter.For a list of parameters, refer toAppendi

Seite 10 - Compatible Products

3-2 Configuring the Serial ConverterIf you connect to a PowerFlex drive and it has either an LED or LCDHIM (Human Interface Module), you can use the HI

Seite 11 - Required Equipment

Configuring the Serial Converter 3-3With DriveExplorer software, you can edit parameters in both the serialconverter and the connected product. On a Po

Seite 12 - Safety Precautions

Important User InformationBecause of the variety of uses for the products described in thispublication, those responsible for the application and use

Seite 13 - Quick Start

3-4 Configuring the Serial ConverterThis section provides detailed instructions on how to use terminalemulation software to access the serial converter

Seite 14 - Modes of Operation

Configuring the Serial Converter 3-5The Connection Description dialog box appears in the HyperTerminalworkspace.Figure 3.3 Connection Dialog Box4. In

Seite 15 - Chapter 2

3-6 Configuring the Serial Converter8. Select the settings shown inFigure 3.4.Important: If you have previously set Parameter 03 - [DF1 RateCfg] to 19.

Seite 16 - Removing the Serial Converter

Configuring the Serial Converter 3-7Figure 3.5 Properties Dialog Box14. Click OK to display the HyperTerminal workspace.15. Press the Enter key until

Seite 17 - Chapter 3

3-8 Configuring the Serial ConverterTo navigate in the terminal emulation softwareThe serial port rate, sometimes called baud rate or DF1 rate, is the

Seite 18 - Using the PowerFlex HIM

Configuring the Serial Converter 3-9By default, when DF1 serial communications are disrupted (e.g., a serialcable is disconnected) and control I/O is b

Seite 19 - Using DriveExplorer

3-10 Configuring the Serial ConverterAfter you change some parameters, you must reset the serial converterfor the new setting to take effect. You can r

Seite 20

Chapter 4TroubleshootingChapter 4 provides information to troubleshoot the serial converter.The serial converter reports its status using status indic

Seite 21

4-2 TroubleshootingDiamond Status IndicatorRX Status IndicatorTX Status Indicator!ATTENTION: Risk of injury or equipment damage exists. If the serialc

Seite 22

Troubleshooting 4-3The following diagnostic items can be accessed using DriveExplorer(version 2.01 or higher).It is normal for the event queue in the

Seite 23

Summary of ChangesThe information below summarizes the changes to the serial converterand documentation since its last release.Serial Converter Change

Seite 24 - Setting the Serial Port Rate

4-4 TroubleshootingFigure 4.2 Example Event Queue in HyperTerminalEventsMany events in the Event queue occur under normal operation. If youencounter

Seite 25 - Setting the Fault Action

Troubleshooting 4-5Table 4.B DPI ModeTo clear the event queue1. Access the event queue using a configuration tool. Refer toConfiguration Tools in Chap

Seite 26 - To reset the serial converter

4-6 TroubleshootingIf you encounter unexpected communications problems or are creatingan application that uses DF1 data, you can view the communicatio

Seite 27 - Troubleshooting

Troubleshooting 4-7Troubleshooting Potential ProblemsDescription ActionYou are unable to establish aconnection between your computerand the serial con

Seite 28 - TX Status Indicator

4-8 TroubleshootingNotes:

Seite 29 - Module Diagnostic Items

Appendix ASpecificationsAppendix A provides the specifications for the serial converter.Topic Page Topic PageCommunications A-1 Environmental A-2Electri

Seite 30

A-2 SpecificationsEnvironmentalTemperatureOperatingStorage0 to +50°C (32 to 122°F)-40 to +85°C (-40 to 185°F)Relative Humidity 5 to 95% non-condensingV

Seite 31 - To clear the event queue

Appendix BSerial Converter ParametersThis chapter presents information about the parameters in the serialconverter.Parameter ListNo. Name and Descript

Seite 32 - To clear DF1 data

B-2 Serial Converter ParametersNo. Name and Description Details05 [Reset Module]Ready No action.Reset Module Resets the serial converter.Set Defaults

Seite 33 - Troubleshooting 4-7

Serial Converter Parameters B-3No. Name and Description Details14 [NAK No Memory](1)Number of NAKs sent by the serial converter because itdid not have

Seite 35 - Specifications

B-4 Serial Converter ParametersNotes:

Seite 36 - Regulatory Compliance

Appendix CFlash UpdatesAppendix C provides information on updating DPI host or peripheralproduct firmware.Please take the following precautions to ensu

Seite 37 - Serial Converter Parameters

C-2 Flash Updates1. In the main menu (Figure 3.6), press 3 to Update Flash program.If the serial converter is connected to a product implementingSCANp

Seite 38

Flash Updates C-32. If the Flash can be completed safely, type Y. The letter “C”repeatedly appears. It is the Xmodem prompt and continues toappear unt

Seite 39

C-4 Flash UpdatesTroubleshooting Potential Flash ProblemsDescription Corrective Action“Transfer Cancelled by RemoteSystem” message appears and theFlas

Seite 40

GlossaryA Application CodeCode that runs in the adapter after the boot code calls it. It performs thenormal operations of the system.B BCCBlock Check

Seite 41 - Flash Updates

Glossary-2DPIDPI is a second generation peripheral communication interface used byvarious Allen-Bradley drives and power products. It is a functionale

Seite 42

Glossary-3H HIM (Human Interface Module)A device that can be used to configure and control a PowerFlex drive.New HIMs (20-HIM-x) can be used to configur

Seite 43

Glossary-4SCANport ProductA device that uses the SCANport communications interface tocommunicate with one or more peripheral devices. For example, a m

Seite 45 - Glossary

Table of ContentsPreface About This ManualRelated Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-1Conventions Used in this

Seite 47 - S SCANport

Glossary-7Notes:

Seite 48 - Z Zero Data

Glossary-8Notes:

Seite 49 - Glossary-5

Glossary-9Notes:

Seite 50 - Glossary-6

Glossary-10Notes:

Seite 51 - Glossary-7

IndexNumerics1203-SSS converter, see serialconverterAaccessing parameters, 3-1Adapter Port parameter, B-1adapter, see serial converterapplication code

Seite 52 - Glossary-8

Index-2EEEPROM, refer to Non-VolatileStorage (NVS)ENQs Received parameter, B-2ENQs Sent parameter, B-2equipmentrequired, 1-3supplied, 1-3error detecti

Seite 53 - Glossary-9

Index-3Pparametersaccessing, 3-1list of, B-1–B-3manual conventions, P-1parity, A-1PCCC, G-3ping, G-3power consumption, A-1power cycle, 3-10products, s

Seite 54 - Glossary-10

Index-4XXmodemdefinition, G-4using to flash firmware, C-1Zzero datadefinition, G-4setting, 3-9

Seite 55 - Numerics

1336 FORCE, 1336 IMPACT, Allen-Bradley, DPI, DriveExplorer,DriveTools 2000, DriveTools32, PowerFlex, SCANport, and SMCDialog Plus are trademarks of Ro

Seite 56

iiAppendix B Serial Converter ParametersParameter List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-1Appendix C Flash Up

Seite 57

Publication 20COMM-UM001A-EN-P – October, 2000 P/N 194884 (01)Copyright 2000 Rockwell International Corporation. All rights reserved. Printed in USA.

Seite 58

PrefaceAbout This ManualRead this preface to become familiar with the rest of the manual.Documentation can be obtained online at http://www.ab.com/man

Seite 59

P-2 About This ManualRockwell Automation offers support services worldwide, with over 75sales/support offices, over 500 authorized distributors, and ov

Seite 60

Chapter 1Getting StartedThe 1203-SSS serial converter provides an electronic communicationsinterface between a computer and any Allen-Bradley producti