Chapter 3 Controller logging
Example:
Retrieve the Unsaved Entry Count using a Get System Value (GSV) ladder instruction
Execution Modification Count
The Execution Modification Count tracks the number of changes that occur that
can change the behavior of a running controller. You can configure the counter to
include or exclude force changes.
The events that cause the Execution Modification Count to increment include the
following.
Online edits tested or assembled
Forces enabled or disabled (if so configured)
Program properties modified
Task properties modified
Controller timeslice modified
You can set this counter to a known value using an SSV instruction.
The following example rung of ladder logic shows how to retrieve the Execution
Modification Count by using a GSV instruction.
32 Rockwell Automation Publication 1756-PM015F-EN-P October 2014