Rockwell-automation FactoryTalk Report Expert User Guide Bedienungsanleitung Seite 68

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 182
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 67
Chapter 5 Understanding Report Templates
68 Rockwell Automation Publication RPTEXP-UM001H-EN-P-June 2014
The bar chart fields:
State Count chart fields:
Item Description
Value State Count
X axis grouping First non-page grouping parameter
Series Second non-page grouping
Total Duration chart fields:
Item Description
Value Total Duration
X axis grouping First non-page grouping parameter
Series Second non-page grouping
The Throughput report template allows you to assess the
performance of a machine as compared to its ideal cycle time. The
ideal cycle time will depend upon the product being produced and is
measured in units of seconds per part.
Query: Performance.
The fields of the report template grid:
Item Description
Total Parts The total number of parts produced.
Running Time The number of seconds the machine was in a running state.
Realized Cycle Time The actual amount of time it took to produce a part. This value is a
ratio of running time to the total number of parts produced. The
calculation for this field is:
RealizedCycleTime = RunningTime / TotalParts.
Throughput
Seitenansicht 67
1 2 ... 63 64 65 66 67 68 69 70 71 72 73 ... 181 182

Kommentare zu diesen Handbüchern

Keine Kommentare