Introduction
The CS300 Bridge Module presents a new opportunity to combine the CS300 I/O structure with the
latest processing and communications features of Trusted
TM
.
Combining the two products will enable CS300 users to benefit from features such as 3-3-2-0
Processor fault tolerance, IEC 1131 programming suite, Ethernet networks, OPC, Ethernet peer to
peer and remote diagnostics. The CS300 Bridge Module replaces the CS300 ICCB in the CS300
Primary chassis.
Any system using the CS300 Bridge Module and Trusted
TM
TMR Processor can also include Trusted
TM
Expanders and I/O modules forming a Hybrid system. To the Trusted
TM
TMR Processor, the Trusted
TM
and CS300 chassis appear in the same system map. All systems using Trusted
TM
TMR Processors
can be seamlessly integrated together.
Upgrade Features
Triple Modular Redundant (TMR), fault tolerant (3-3-2-0) operation
Dedicated hardware and software test regimes which provide very fast fault
recognition and response times
Automatic fault handling without nuisance alarming
Hot replacement, self-configuration.
Interfaces to Trusted
TM
TMR Expander Bus
Front panel indicators that show module health data transmission status
TÜV certification and IEC61508 SIL3
Seitenansicht 0
1 2 3 4 5 6 ... 33 34

Inhaltsverzeichnis

Seite 1 - CS300 Bridge Module

TrustedTM PD-8162 Issue 01 Apr 08 PD-8162 1 TrustedTM CS300 Bridge Module Introduction The CS300 Bridge Module presents a new opportunity to combine

Seite 2

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 10 2.2. TC-322-02 Interface Cable assembly The interface cable connects from the TrustedTM Int

Seite 3 - Figures

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 11 Figure 5 TrustedTM controller chassis rear view Figure 5 shows a four socket version of the

Seite 4 - Issue 01 Apr 08 PD-8162 4

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 12 The four backplane jumpers 0,1,2,3 (A,B,C) represent the binary address bits 1,2,4 & 8

Seite 5 - Associated Documents

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 13 3. Application All CS300 I/O modules are configured using the IEC1131 application Toolset p

Seite 6 - Associated Equipment

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 14 The first chassis to be created is a CS300 8162. This includes the bridge modules in place

Seite 7 - 1. Description

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 15 Figure 12 Jumper Setting This chassis then links into the extension chassis BIC, which is l

Seite 8 - 1.4. Function

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 16 Having added all the chassis in the system, the next step is to insert modules. For each mo

Seite 9 - 2. Installation

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 17 3.2. Board definitions There are no restrictions in the order of the boards set out in the

Seite 10

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 18 3.3. Module – 8162 (Bridge Module) DESCRIPTION This definition provides module status for

Seite 11 - 2.3. Module Configuration

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 19 3.4. Module – bic (bus interface controller) DESCRIPTION This definition provides module

Seite 12

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 2 Issue Record Issue Number Date Revised by Technical CheckAuthorised by Modifica

Seite 13 - 3. Application

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 20 3.5. Module – pi632 / pi732 (analogue input module) DESCRIPTION This definition will open

Seite 14

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 21 3.6. Module – pi641 / pi741 (analogue output module) DESCRIPTION This definition will open

Seite 15

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 22 RACK 4: (CALIB) 4 BOOLEAN outputs (one per channel) which determine if the AO output data

Seite 16

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 23 3.7. Module – pi616_5 / pi616_9 / pi716 / pi717 (digital input module) DESCRIPTION This de

Seite 17 - 3.2. Board definitions

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 24 3.8. Module – pi626 / pi726 (digital output module) DESCRIPTION This definition will open

Seite 18

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 25 RACK 3: (FAULTS) 4 INTEGER inputs Word 1 Discrepancy errors, channels 1-16 (bit 0 = ch

Seite 19

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 26 3.9. Module – pi627 / pi727 / pi627_fs / pi727_fs (digital output module) DESCRIPTION This

Seite 20

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 27 RACK 3: (FAULTS) 4 INTEGER inputs Word 1 Discrepancy errors, channels 1-16 (bit 0 = ch

Seite 21

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 28 3.10. Module – dmx_m (de-multiplexed display driver) DESCRIPTION This definition will open

Seite 22

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 29 3.11. Module – dmx_o (de-multiplexed display driver card) DESCRIPTION This definition will

Seite 23

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 3 Table of Contents 1. Description...

Seite 24

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 30 4. Operation Figure 16 Front Panel Layout

Seite 25

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 31 4.1. Front Panel Indicators and Controls 4.1.1. Tx & Rx Indicators Flashing amber LED

Seite 26

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 32 5. Fault Finding and Maintenance The TrustedTM TMR Processor provides fault monitoring, sel

Seite 27

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 33 6. Specifications Supply Voltage 5.4Vdc ± 5% Heat Dissipation 3W max Operating Temperatur

Seite 28

TrustedTM PD-8162 Issue 01 Apr 08 PD-8162 34

Seite 29

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 4 Figure 9 CS300 Main Chassis...

Seite 30 - 4. Operation

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 5 Precautionary Information WARNING Warning notices call attention to the use of materials, pr

Seite 31 - 4.1.2. Health Indicator

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 6 Associated Equipment Part Number Product Name Description T8043 CS300 Toolset Library Add

Seite 32

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 7 1. Description 1.1. Overview The CS300 Bridge Module enables connection between a CS300 I/O

Seite 33 - 6. Specifications

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 8 1.2. Power Distribution Each of the Bridge modules is powered from triple redundant PSUs (si

Seite 34 - PD-8162

TrustedTM CS300 Bridge Module Issue 01 Apr 08 PD-8162 9 2. Installation 2.1. Module Each of the three Bridge modules replaces one of the CS300 ICCB