Rockwell-automation CIP Motion Popular Configuration Drawing With Note Bedienungsanleitung Seite 5

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 4
PowerFlex 4
Class VFD
POINT I/O
POINTGuard I/O
(Safety I/O)
Kinetix 6500 Servo Drive
Stratix 6000 Switch
ControlLogix
Integrated Motion on EtherNet/IP: 8 Axis
Ring/Star with PowerFlex 755 and Safety
Note: Performance is what we tested,
not the max capacity
Safety Capacity
Distributed Safety functionality
across the network supported
in such products as CompactBlock
Guard I/O, POINT Guard I/O,
Kinetix 6500, and PowerFlex 755
1783-ETAP
1783-ETAP
The 1783-ETAP can be used to
connect devices that do not currently
have the 2 port embedded linear/ring
technology.
PanelView Plus
CompactBlock Guard I/O
(Safety I/O)
Plant MRP
System, Database,
Order Tracking Systems
Configuration
EtherNet/IP, DeviceNet and RA
Controllers enable business systems
to plant floor communications, providing
the ability to share thousands of pieces of
information with no programming required
P
OWER
Power Supply
RUN I/O
R
S232
OK
FORCE
B
AT
RUN REM PROG
Logix5562S
SAFETY
R
UN
SAFETY
T
ASK
OK
B
AT
Logix55LSP
GuardLogix *
OK
AB
A
B
CPU
EtherNet/IP
OK
A
B
1756-EN2TR
ArmorBlock
SOE I/O
Module
Capacity
Switch Configurations Options
Can use embeddeded, unmanaged, or managed switches
from any switch manufacturer.
Recommended Rockwell Automation switchces available include:
-Stratix 8000 and 6000 Managed Switches
-Stratix 2000 unmanaged switch
2 port embedded linear/ring technology available in:
- 1756-EN2TR ControlLogix module
- 1756-EN3TR ControlLogix module
- 1734-AENTR Point I/O Adapter
- ArmorBlock SOE I/O module
- Kinetix 6500
1783-ETAP Standalone 3 port tap allows any single port
device to participate
Switch Performance
In many applications an external switch is not required due to
the high precision 2 port embedded linear/ring technology included in the products
In topologies where an external switch is used (e.g. Star), either a managed or
unmanaged switch can be used, depending on your application requirements.
Integrated Motion on EtherNet/IP Allows you to Use One Network to Integrate High Performance Servo & AC Drive Control,
Distribute I/O, HMI, and other EtherNet/IP Devices, for Standard and Safety Applications
Kinetix 6500 Configuration
Full integrated motion support for Kinetix 6500/ PowerFlex 755*
using EtherNet/IP
Can configure for position, velocity, or torque control
RSLogix 5000 common integrated motion programming, configuration,
commissioning,and drive dignostic & maintenance tools for the
Kinetix 6500/ PowerFlex 755*
Use same Motion instructions for Kinetix 6500/PowerFlex 755*
Safety Options:
- SIL 3, Cat 4, PLe Safe Torque Off
- SIL 3, Cat 4, PLe Safe Speed (dual encoder)
- SIL 2 Pld Safe Speed (single encoder)
Kinetix 6500 Performance
High speed registration input on
Kinetix drive can trigger a motion
task in RSLogix 5000 for faster
event task performance
ControlLogix/1756-ENXT(R)
Performance
• 8 drives/ms using either a 1756-EN2T(R)
or 1756-EN3TR module
POINT I/O Capacity
The maximum is 63 POINT I/O modules per adapter
1734-AENTR EtherNet/IP adapter utilizes embedded
switch technology to support linear or ring topologies
You can mix Safety and Standard Point I/O modules
in the same rack
PowerFlex 755*
Architecture
Class Drive
PowerFlex 755 VFD Performance
Speed, Position, and Torque Control
PowerFlex 755 VFD Capacity
1-650Hp
.75-400kW
400/480VAC & 540/650VDC
Embedded EtherNet/IP
ArmorBlock SOE I/O Module Capacity
Sequence of Events (SOE) module
Time stamp data can be used for
motion soft registration support
Includes 100us transition time stamp
Integrated Motion on EtherNet/IP Configuration
Mix and match Motion, Standard I/O ,
and Safety devices on one network.
Either Star, Linear, or Device Level Ring (DLR)
topologies can be used (or a mix of these topologies)
* Optional Modules
GuardLogix only
required for safety
applications
Camera
PowerFlex 755 VFD Configuration
Full integrated motion support for
PowerFlex 755*/Kinetix 6500 using EtherNet/IP
Can configure for position, velocity, torque,
or V/Hz control
RSLogix 5000 common integrated motion
programming, configuration, commissioning, and
motion tools for the PowerFlex 755*/Kinetix 6500
Use same Motion instructions for Kinetix 6500/
PowerFlex 755*
Safety Options:
- SIL 3, Cat 3, PLe Safe Torque Off
- SIL 3, Cat 4, PLe Safe Speed
ControlLogix/1756-ENXT(R) Capacity
• 1-8 position configured drives
with 1756-EN2T(R)
• 1-255 position configured drives
with 1756-EN3TR (with multiple conrollers)
• Unlimited velocity, torque, and
Vhz configured drives
Logix controller drive limit of 100 drives
ControlLogix/1756-ENXT(R)
Configuration
• USB Port on 1756-EN2T(R)/EN3TR
provides easy access to module
and networks for configuration,
a
nd troubleshooting
Kinetix 6500 Capacity
460V AC Input Voltage
1.8 kW to 22 kW
0.18-134 Nm torque (1.59-1186 lb-in)
• Up to 7250 rpm
• Up to 2,000,000 feedback resolution
• Embedded EtherNet/IP
PV+
HMI
Device Level Ring (DLR)
* RSLogix 5000 support for PowerFlex 755 with Integrated Motion available August 2010.
Publication IASIMP-QR019B-EN-P May 2010
Supersedes Publication IASIMP-QR019A-EN-P March 2010
IASIMP-QR019B-EN-P.qxp:Layout 1 5/4/10 11:34 AM Page 5
Seitenansicht 4
1 2 3 4 5 6

Kommentare zu diesen Handbüchern