Rockwell-automation 873P Ultrasonic Single & Dual Discrete Output Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Rockwell-automation 873P Ultrasonic Single & Dual Discrete Output herunter. Rockwell Automation 873P Ultrasonic Single & Dual Discrete Output Sensors Installation Instruction User Manual [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 6
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Rockwell Automation 873P-IN003A-EN-P—October 2014
Installation Instructions
Ultrasonic Single & Dual Discrete Output Sensors
IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.
Specifications
P1–(1) PNP discrete output or P2–(2) PNP discrete outputs
If P1, the suffix of the sensor is D4 (QD, 4-pin); if P2, the suffix of the sensor is D5 (QD, 5-pin).
Metallic target 100 x 100 mm (3.94 x 3.94 in.)
Metallic target 200 x 200 mm (7.87 x 7.87 in.)
Metallic target 400 x 400 mm (15.7 x 15.7 in.)
Model
873P-D18-
400-D
873P-D18-
900-D
873P-D18-
2200-D
873P-D30-
2500-D
873P-D30-
3500-D
873P-D30-
6000-D
Certifications
cULus Listed and CE Marked for all applicable directives
Rated Sensing Distance
50…400 mm
(1.97…15.7 in.)
100…900 mm
(3.94…35.4 in.)
200…2200 mm
(7.87…88.6 in.)
200…2500 mm
(7.87…98.4 in.)
250…3500 mm
(9.84…137.8 in.)
350…6000 mm
(13.8…236.2 in.)
Teachable Sensing Range
100…400 mm
(3.94…15.7 in.)
100…900 mm
(3.94…15.7 in.)
200…2200 mm
(7.87…15.7 in.)
200…2500 mm
(7.87…15.7 in.)
250…3500 mm
(9.84…15.7 in.)
350…6000 mm
(13.8…236.2 in.)
Blind Zone
0…50 mm
(0…1.97 in.)
0…100 mm
(0…3.94 in.)
0…200 mm
(0…7.87 in.)
0…200 mm
(0…7.87 in.)
0…250 mm
(0…9.84 in.)
0…350 mm
(0…137.8 in.)
Beam Angle ±8° ±7° 14° ±1° 15° ±2°
Sensitivity Adjustment Push button
Repeatability 0.1% up to 3.5 m (11.5 ft) and 0.2% to 6 m (19.7 ft)
Hysteresis <1% of the full scale value
Resolution 1 mm (0.04 in.) 2 mm (0.08 in.) 3 mm (0.12 in.) 2 mm (0.08 in.) 4 mm (0.16 in.) 6 mm (0.24 in.)
Accuracy 0.1% of sensing range
Ripple 5%
Current Consumption ≤50 mA
Protection Type Short circuit, reverse polarity, transient noise, overload
Output Current 100 mA
Leakage Current ≤10 μA @ 30 V
Transducer Frequency 300 kHz 200 kHz 150 kHz 112 kHz 75 kHz
Voltage Drop 2.2V max
Output Type
P1 or P2
Switching Frequency 10 Hz 4 Hz 1 Hz 2 Hz 1 Hz
Response Time 50 ms 125 ms 500 ms 250 ms 500 ms
Time Delay before Availability
≤500 ms (single discrete output);
≤900 ms (double discrete output)
Temperature Range -20…+60° C (-4…+140° F) -20…+70° C (-4…+158° F)
Temperature Compensation Yes
Temperature Drift ±5%
Housing Material Plastic—PBT
Active Head Material Epoxy—glass resin
Ingress Protection Rating IP67 (EN 60529)
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - Installation Instructions

Rockwell Automation 873P-IN003A-EN-P—October 2014Installation InstructionsUltrasonic Single & Dual Discrete Output SensorsIMPORTANT: SAVE THESE IN

Seite 2 - One Set Point Function

Rockwell Automation 873P-IN003A-EN-P—October 20142 873P Ultrasonic Single & Dual Output SensorsSingle Discrete N.O./N.C. OutputNormally-open Lo

Seite 3 - Other Functions

873P Ultrasonic Single & Dual Output Sensors 3Rockwell Automation 873P-IN003A-EN-P—October 2014One Set Point FunctionDual discrete sensors will

Seite 4 - Wiring Diagrams

Rockwell Automation 873P-IN003A-EN-P—October 20144 873P Ultrasonic Single & Dual Output Sensorsvaries depending on the type(s) of sensors used

Seite 5 - Dimensions [mm (in.)]

873P Ultrasonic Single & Dual Output Sensors 5Rockwell Automation 873P-IN003A-EN-P—October 2014Dimensions [mm (in.)]M18M30M383(0.12)M12x114(0.5

Seite 6

6 873P Ultrasonic Single & Dual Output SensorsPower, Control and Information Solutions HeadquartersAmericas: Rockwell Automation, 1201 South Se

Kommentare zu diesen Handbüchern