4-4 Operations
Publication 855T-UM001C-EN-P May 2005
Parameters 7, 9, 11, 13, 15 — Module Type
In normal operation the device will permit configuration of each module type. The default
type is 8, Invalid Module.
IMPORTANT
Although it is allowed, it is not recommended that strobe, sound, or
flashing modules be used with modes that flash.
Table 4.G Module Type
Type Module Type Module
0 Incandescent 5 Combination Strobe/Sound
1 LED 6 Single Tone Sound
2 Strobe 7 Dual Tone Sound
3 Combination Incandescent/Sound 8 Invalid Module
4 Combination LED/Sound
IMPORTANT
The module type list is abbreviated. If the module is a rotating, flashing,
or steady LED, then select the LED as the module type. If the module
type is a flashing incandescent, then select Incandescent as the module
type. The same logic applies to combination light/sound type modules.