Troubleshooting
Chapter 11
11-137
IGBT Test Procedure The following procedure provides the steps needed to properly test the
IGBT modules to determine if replacement is necessary.
1. Remove all power to the drive. Remove the front cover from the drive.
2. Label and remove the three motor wires from the drive terminals U, V
and W.
3. Access to the IGBT modules must be gained by removing the
following boards:
On 8510A-A04 and A06 drives remove the CPU, Gate Drive and I/O
Boards.
On 8510A-A11 and A22 drives remove the Main Control (and I/O)
Board.
4. The 8510A-A04 and A06 drives have two modules, while the
8510A-A11 and A22 drives have six. For proper testing, each module
must be checked four different ways. The procedure for 8510A-A04
and A06 drives is shown in Figure 11.5. The procedure for 8510A-A11
and A22 drives is shown in Figure 11.6.
On 8510A-A11 and A22 drives the IGBT module will have 4 spade
lugs for the gate connection. Use these as a reference point for
orientation.
Measurements must be taken with a Digital Voltmeter (DVM) equipped
with a Diode setting. The connection polarity for the meter is shown
in each figure.
A reasonable ohm reading would be 1 meg to infinity. A reasonable
voltage drop would be 450 - 700mV. If a measurement differs
appreciably from these values, the module is bad and the Power Unit
must be replaced.
5. When testing/replacement is complete, replace board(s), cover and
check for proper operation.