Chapter 8
Defining Strings for Serial Ports and Viewports
8 25
Value Out of Range: If you try to enter a number which is not valid,
such as a gage number 65 (there are only 64 gages), the calculator pad
will flash the message Value Out of Range. If this happens, pick an
appropriate number, and then pick the Enter key again.
Figure 8.5 Using the calculator pad for selecting the event source
Calculator Pad
Gage box
Selecting the Source Condition
After specifying the event source (Master Range, Gage, etc.) you next
specify the source condition.
Select the source condition by picking the topmost box on the Event menu:
Source condition box
When you pick the source condition box successively, it cycles through the
available source condition options. The available options for source
condition depend on which type of event source is currently selected:
With Master Range selected, the source condition options are:
Print Always String sent at the completion of each inspection. This
is the default setting.
Print on PASS String sent only if the master range passes.
Print on FAIL String sent only if the master range fails.