Publication 999-126 - February 1996
18 Installation & Hook-Up
Figure 2.7
Wiring a 1326AB-MOD-VD:256 Master/Vernier Dual Resolver package to the
Axis 0 Resolver plugs or the Axis 1 Resolver plugs on the REC.
Important: Anchor the cable so that no more than 2 feet of cable is
left unsupported. The excessive weight of an unanchored
cable could pull the plug out of the connector.
Figure 2.8
Wiring a 1326AB-MOD-VD x:x resolver package to the Axis 0 Resolver plugs
or the Axis 1 Resolver plugs on the REC
Important: Anchor the cable so that no more than 2 feet of cable is
left unsupported. The excessive weight of an unanchored
cable could pull the plug out of the connector.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Green N
Black R
Violet M
Black P
Blue J
Black K
Red D
Black F
Orange E
Black G
White A
Black B
Resolver
Assembly
1326AB-MOD-VD :256
1326-CVUxx Cable
Internal fault relay contact
Chassis Ground
Axis Fault
N.O.
Chassis Ground
Plug A
Plug B
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Red D
Black F
Orange E
Black G
White A
Black B
Resolver
Assembly
1326AB-MOD-VD x:x
1326-CVUxx Cable
Internal fault relay contact
Chassis Ground
Axis Fault
N.O.
Chassis Ground
Plug A
Plug B