QUICK START
ARMORSTART
®
DISTRIBUTED
MOTOR CONTROLLER
Getting Started
BULLETIN 284D
Introduction This guide provides the basic information required to start up your
ArmorStart
®
Distributed Motor Controller. Factory default settings
and information regarding installing, programming, and DeviceNet™
Node Commissioning are described here. For detailed information on
specific product features or configurations, refer to the ArmorStart
user manual, Publication 284-UM001*-EN-P.
This guide is intended for qualified service personnel responsible for
setting up and servicing these devices. You must have previous
experience with and a basic understanding of electrical terminology,
configuration procedures, required equipment, and safety precautions.
You should understand DeviceNet network operations, including how
slave devices operate on a network and communicate with a
DeviceNet master. You should also be familiar with RSNetWorx™
for DeviceNet. You must use RSNetWorx for DeviceNet revision
3.21 service pack 2 or later. This software package is referred to
often in this manual. Rockwell Automation product EDS files are
available on the internet at: http://www.ab.com/networks/eds
.
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - MOTOR CONTROLLER

QUICK STARTARMORSTART® DISTRIBUTED MOTOR CONTROLLERGetting StartedBULLETIN 284D Introduction This guide provides the basic information required to sta

Seite 2

10 Publication 284D-QS001D-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturi

Seite 3 - Entrance

Publication 284D-QS001D-EN-P - July 2006 11Wiring Power, Control, Safety Monitor Inputs, and Ground Wiring Table 1 provides the power, control,

Seite 4 - ArmorConnect™ Connectivity

12 Publication 284D-QS001D-EN-P - July 2006Table 2 Power, Control, Safety Monitor, and Ground Terminal Designations➊ Only available with the Sa

Seite 5 - 5

Publication 284D-QS001D-EN-P - July 2006 13ArmorConnect Power Media DescriptionThe ArmorStart Power Media offers both three-phase and control p

Seite 6 - 6

14 Publication 284D-QS001D-EN-P - July 2006Figure 11 Control Power Media System Overview➏ Control Power Media Patchcords - PatchCord cable wit

Seite 7 - 7

Publication 284D-QS001D-EN-P - July 2006 15ArmorStart with ArmorConnect ConnectivityInstalling ArmorConnect Power Media using Cord GridsContro

Seite 8 - Connectivity

16 Publication 284D-QS001D-EN-P - July 2006ArmorConnect Cable RatingsThe ArmorConnect Power Media cables are rated per UL Type TC 600V 90 °C Dr

Seite 9 - 9

Publication 284D-QS001D-EN-P - July 2006 17Group Motor Installations for USA and Canada MarketsThe ArmorStart Distributed Motor controllers are

Seite 10 - 10

18 Publication 284D-QS001D-EN-P - July 2006The working space around the ArmorStart may be minimized as the ArmorStart does not require examinat

Seite 11 - Conduit Entrance

Publication 284D-QS001D-EN-P - July 2006 19AC Supply ConsiderationsUngrounded Distribution SystemsDisconnecting MOVSTo prevent drive damage, th

Seite 13 - Description

20 Publication 284D-QS001D-EN-P - July 2006Figure 13 Jumper RemovalLED Status Indication The LED Status Indication provides 4 status LEDs and a

Seite 14 - Enclosure

Publication 284D-QS001D-EN-P - July 2006 21Figure 14 LED Status Indication and ResetDeviceNet Node CommissioningEstablishing a DeviceNet Node A

Seite 15 - 15

22 Publication 284D-QS001D-EN-P - July 2006To set an address using the hardware rotary switches, simply set the switches to the desired node ad

Seite 16 - Three-Phase Power Media

Publication 284D-QS001D-EN-P - July 2006 23Default Input and Output (I/O) Assembly FormatsThe I/O assembly formats for the ArmorStart are ident

Seite 17 - 17

24 Publication 284D-QS001D-EN-P - July 2006Setting the Motor OL CurrentThe product should now be configured and communicating on the network. T

Seite 18 - 18

Publication 284D-QS001D-EN-P - July 2006 25Bulletin 284 PararmetersTable 6 Basic Program Group for Sensorless Vector Performance➊ Stop drive be

Seite 19 - AC Supply Considerations

26 Publication 284D-QS001D-EN-P - July 2006Table 7 Basic Program Group for Sensorless Vector Control➊ Stop drive before changing this parameter

Seite 20 - Figure 13 Jumper Removal

Publication 284D-QS001D-EN-P - July 2006 27Quick Reference TroubleshootingThere are four LEDs on the front of the ArmorStart that can provide a

Seite 21 - Commissioning

28 Publication 284D-QS001D-EN-P - July 2006Fault LED Indications for Bulletin 284D ArmorStart Distributed Motor ControllersTable 10 Controller

Seite 22

Publication 284D-QS001D-EN-P - July 2006 29Internal Drive FaultsA fault is a condition that stops the drive. There are two fault types.Table 11

Seite 23 - (4 bytes)

Publication 284D-QS001D-EN-P - July 2006 3Installation The ArmorStart Distributed Motor Controller is convection cooled. Operating temperature

Seite 24 - Setting the Motor OL Current

30 Publication 284D-QS001D-EN-P - July 2006Table 12 Fault Types, Descriptions, and Actions➊ See Table 11 for internal drive fault types.No. Fau

Seite 25 - Bulletin 284 Pararmeters

Publication 284D-QS001D-EN-P - July 2006 31Table 12 Fault Types, Descriptions, and Actions (Continued)➊ See Table 11 for internal drive fault

Seite 26 - IMPORTANT

32 Publication 284D-QS001D-EN-P - July 2006Figure 17 Bulletin 284 ArmorStart➋ Available only with the Bulletin 284 with sensorless vector contr

Seite 27 - Troubleshooting

Publication 284D-QS001D-EN-P - July 2006 33Accessories Table 13 DeviceNet Media ➊0➊See Publication M116-CA001A-EN-P for complete cable selectio

Seite 28 - Distributed Motor Controllers

34 Publication 284D-QS001D-EN-P - July 2006Table 14 Sensor Media ➊0➊See Publication M116-CA001A-EN-P for complete cable selection information.➋

Seite 30

Publication 284D-QS001D-EN-P — July 2006 41053-384-02Superecedes Publication 284D-QS001C-EN-P — September 2005 Copyright ©2006 Rockwell Automation, In

Seite 31

4 Publication 284D-QS001D-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Seite 32 - 32

Publication 284D-QS001D-EN-P - July 2006 5Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Seite 33 - Table 13 DeviceNet Media

6 Publication 284D-QS001D-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Seite 34 - Table 15 Sealing Caps

Publication 284D-QS001D-EN-P - July 2006 7Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Seite 35

8 Publication 284D-QS001D-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Seite 36 - Trademark List

Publication 284D-QS001D-EN-P - July 2006 9Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Kommentare zu diesen Handbüchern

Keine Kommentare