Installation Instructions
PowerFlex
®
DC Drive - Frame C Switching
Power Supply Circuit Board Fuse Replacement
What This Kit Includes
Two Fuses:
Frame C drives with Switching Power Supply circuit board, SW3-32,
rev. H & below
, one 5x20mm, 2.5A 250V fuse and one 5x20mm,
3.15A 250V fuse
Frame C drives with Switching Power Supply circuit board, SW3-32,
rev. I & above
, two 5x20mm, 2.5A 250V fuses
Two fuse holder caps
What You Need to Do
1. Remove and lock-out all incoming power to the drive.
2. Disconnect the DPI cable from the HIM assembly (if present).
ATTENTION: To avoid an electric shock hazard, ensure that
all power to the drive has been removed before performing the
following.
L1 L2 L3
O
I
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - PowerFlex

Installation InstructionsPowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement What This Kit Includes• Two Fuses:– Fram

Seite 2

2 PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement 3. Loosen, but do not remove, the screws that secure the bottom

Seite 3

PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement 3 5. Disconnect the HIM Communication cable from the connector on

Seite 4 - Remove cable

4 PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement 7. Loosen the two captive screws at the top of the Control EMI s

Seite 5 - F2 = 2.5A

PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board Fuse Replacement 5 10. Insert the new fuses into the appropriate holders and replac