Par Parameter Name Factory Default Programmed Value Par Parameter Name Factory Default Programmed Value
288 Stop Owner Read Only 1 Output Freq Read Only
289 Start Owner Read Only 2 Commanded Freq Read Only
290 Jog Owner Read Only 3 Output Current Read Only
291 Direction Owner Read Only 4 Torque Current Read Only
292 Reference Owner Read Only 5 Flux Current Read Only
293 Accel Owner Read Only 6 Output Voltage Read Only
294 Decel Owner Read Only 7 Output Power Read Only
295 Fault Clr Owner Read Only 8 Output Powr Fctr Read Only
296 MOP Owner Read Only 9 Elapsed MWh Read Only
297 Local Owner Read Only 10 Elapsed Run Time Read Only
300 Data In A1 0 11 MOP Frequency Read Only
301 Data In A2 0 12 DC Bus Voltage Read Only
302 Data In B1 0 13 DC Bus Memory Read Only
303 Data In B2 0 16 Analog In1 Value Read Only
304 Data In C1 0 17 Analog In2 Value Read Only
305 Data In C2 0 26 Rated kW Read Only
306 Data In D1 0 27 Rated Volts Read Only
307 Data In D2 0 28 Rated Amps Read Only
310 Data Out A1 0 29 Control SW Ver Read Only
311 Data Out A2 0 40 Motor Type Induction
312 Data Out B1 0 41 Motor NP Volts Based on Drive Rating
313 Data Out B2 0 42 Motor NP FLA Based on Drive Rating
314 Data Out C1 0 43 Motor NP Hertz Based on Drive Cat. No.
315 Data Out C2 0 44 Motor NP RPM 1750 RPM
316 Data Out D1 0 45 Motor NP Power Based on Drive Rating
317 Data Out D2 0 46 Mtr NP Pwr Units Based on Drive Rating
320 Anlg In Config 0 47 Motor OL Hertz Motor NP Hz/3
321 Anlg In Sqr Root 0 48 Motor OL Factor 1.00
322 Analog In 1 Hi 10.0 Volt 53 Torque Perf Mode Sensrls Vect
323 Analog In 1 Lo 0.0 Volt 54 Maximum Voltage Drive Rated Volts
324 Analog In 1 Loss Disabled 55 Maximum Freq 110.0 or 130.0 Hz
325 Analog In 2 Hi 10.0 Volt 56 Compensation xxxxxxxxxxxxxx11
326 Analog In 2 Lo 0.0 Volt 57 Flux Up Mode Manual
327 Analog In 2 Loss Disabled 58 Flux Up Time 0.00 secs
341 Anlg Out Absolut xxxxxxxxxxxxxxx1 61 Autotune Calculate
342 Analog Out1 Sel Output Freq 62 IR Voltage Drop Based on Drive Rating
343 Analog Out1 Hi 10.00 Volt 63 Flux Current Ref Based on Drive Rating
344 Analog Out1 Lo 0.00 Volt 69 Start/Acc Boost Based on Drive Rating
361 Digital In1 Sel Stop - CF 70 Run Boost Based on Drive Rating
362 Digital In2 Sel Start 71 Break Voltage [Motor NP Volts] x 0.25
363 Digital In3 Sel Auto/Manual 72 Break Frequency [Motor NP Freq] x 0.25
364 Digital In4 Sel Speed Sel 1 80 Speed Mode Open Loop
365 Digital In5 Sel Speed Sel 2 81 Minimum Speed 0.0 Hz
366 Digital In6 Sel Speed Set 3 82 Maximum Speed
50.0 or 60.0 Hz
(Dep. on voltage class)
380 Digital Out1 Sel Fault 83 Overspeed Limit 10.0 Hz
381 Dig Out1 Level 0.0 84 Skip Frequency 1 0.0 Hz
382 Dig Out1 OnTime 0.00 Secs 85 Skip Frequency 2 0.0 Hz
383 Dig Out1 OffTime 0.00 Secs 86 Skip Frequency 3 0.0 Hz
384 Digital Out2 Sel Run 87 Skip Freq Band 0.0 Hz
385 Dig Out2 Level 0.0 90 Speed Ref A Sel Analog In 2
386 Dig Out2 OnTime 0.00 Secs 91 Speed Ref A Hi [Maximum Speed]
387 Dig Out2 OffTime 0.00 Secs 92 Speed Ref A Lo 0.0 Hz
93 Speed Ref B Sel Preset Spd1
94 Speed Ref B Hi [Maximum Speed]
95 Speed Ref B Lo 0.0 Hz
96 TB Man Ref Sel Analog In 1
97 TB Man Ref Hi [Maximum Speed]
98 TB Man Ref Lo 0.0 Hz
100 Jog Speed 10.0 Hz