13 12 Input/12 Output Discrete Embedded TTL I/O Module with Pulse Width Modulation and DeviceLogix
Publication 1799-IN008A-EN-P - July 2005
Configure DeviceLogix Parameters
Use the Function Block Editor supplied with RSNetWorx for DeviceNet software to
configure DeviceLogix parameters.
Configure the DeviceLogix parameters listed in the following table:
Output Fault Value Controls the value that outputs will have when the output
fault state is set to ‘use fault value.’
Consumed I/O Assembly Lets you select size of consumed data.
Network Status Override Lets local logic override output behavior when the module is
not online.
Comm Status Override Allows local logic to override output behavior when
communications is faulted or idled.
Quick Start Disables Autobaud, decreasing startup time.
TIP
For more information on using the Function Block Editor, refer to
the DeviceLogix User Manual, publication ACIG-UM001, as well
as the online help supplied with RSNetWorx for DeviceNet
software.
Parameter Selection
Function Blocks Supported Boolean
Latches
Timers
Counters
Maximum Number of Function Blocks in a
Configuration
72
Function Block Processing Time 2 msec/24 blocks
4 msec/28 blocks
6 msec/72 blocks
Network Input Bits 32
Network Output Bits 16
Parameter Description