Publication 1788-IN052D-EN-P - February 2007
Installation Instructions
ControlNet-to-DeviceNet Linking Device
Catalog Number 1788-CN2DN
Topic Page
Important User Information 2
About the CN2DN Linking Device 7
Parts List 8
Required System Components 9
Install the CN2DN Device 9
Mount the CN2DN Device on a DIN Rail 10
Mount the CN2DN Device on a Panel or Other Fixture 12
Wire a Power Supply to the CN2DN Device 13
Set the Node Addresses and Communication Rate 15
Connect the CN2DN Device to a ControlNet Network 16
Connect the CN2DN Device to a DeviceNet Network 17
Uninstall the CN2DN Linking Device 19
Interpret the LED Indicators 21
Troubleshoot the DeviceNet Network 29
Troubleshoot the ControlNet Network 46
Specifications 47
Additional Resources 51
Seitenansicht 0
1 2 3 4 5 6 ... 51 52

Inhaltsverzeichnis

Seite 1 - Installation Instructions

Publication 1788-IN052D-EN-P - February 2007Installation InstructionsControlNet-to-DeviceNet Linking DeviceCatalog Number 1788-CN2DNTopic PageImportan

Seite 2 - Important User Information

10 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Mount the CN2DN Device on a DIN RailComplete the following st

Seite 3

ControlNet-to-DeviceNet Linking Device 11Publication 1788-IN052D-EN-P - February 20073. Clip each of the end anchors onto the DIN rail next to the

Seite 4

12 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20075. If you are mounting your CN2DN device in a high-vibration

Seite 5 - Environment and Enclosure

ControlNet-to-DeviceNet Linking Device 13Publication 1788-IN052D-EN-P - February 2007Wire a Power Supply to the CN2DN DeviceThe CN2DN device requi

Seite 6 - ATTENTION

14 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20073. Loosen the two left-most terminal screws of the power conn

Seite 7

ControlNet-to-DeviceNet Linking Device 15Publication 1788-IN052D-EN-P - February 2007Set the Node Addresses and Communication RateComplete the fol

Seite 8 - 1788-CN2DN Parts

16 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Connect the CN2DN Device to a ControlNet NetworkComplete the

Seite 9 - Install the CN2DN Device

ControlNet-to-DeviceNet Linking Device 17Publication 1788-IN052D-EN-P - February 2007Connect the CN2DN Device to a DeviceNet NetworkComplete the f

Seite 10 - Press Forward

18 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20072. Wrap the end of the cable with 38 mm (1.5 in.) of shrink w

Seite 11

ControlNet-to-DeviceNet Linking Device 19Publication 1788-IN052D-EN-P - February 2007The resistor should bridge the blue and white terminal caviti

Seite 12 - Mount Tabs (Optional Use)

2 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Important User InformationSolid state equipment has operationa

Seite 13 - + - +

20 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20074. To remove the CN2DN linking device from the DIN rail, pull

Seite 14 - IMPORTANT

ControlNet-to-DeviceNet Linking Device 21Publication 1788-IN052D-EN-P - February 2007Interpret the LED IndicatorsUse the LED indicators on the CN2

Seite 15 - CN2DN Device Switches

22 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Module StatusUse the following table to interpret your Module

Seite 16

ControlNet-to-DeviceNet Linking Device 23Publication 1788-IN052D-EN-P - February 2007Green, flashing The CN2DN device is functioning but not commu

Seite 17 - Braided Shield

24 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Linking Activity StatusThe Linking Activity LED indicator dis

Seite 18 - (1.5 in.)

ControlNet-to-DeviceNet Linking Device 25Publication 1788-IN052D-EN-P - February 2007ControlNet Network StatusThe CNet A and CNet B LED indicators

Seite 19

26 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007DeviceNet Network StatusThe DeviceNet network indicators, DNe

Seite 20

ControlNet-to-DeviceNet Linking Device 27Publication 1788-IN052D-EN-P - February 2007Green, steady One or more devices connected and communicating

Seite 21 - Interpret the LED Indicators

28 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007DNet I/O Status IndicatorLED Indicator I/O Device Status Reco

Seite 22 - Module Status

ControlNet-to-DeviceNet Linking Device 29Publication 1788-IN052D-EN-P - February 2007Troubleshoot the DeviceNet NetworkIf DeviceNet network commun

Seite 23 - Module Status Indicator

ControlNet-to-DeviceNet Linking Device 3Publication 1788-IN052D-EN-P - February 2007North American Hazardous Location ApprovalThe following Inform

Seite 24 - Linking Activity Status

30 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200770 The address of the device is already in use by another dev

Seite 25 - ControlNet Network Status

ControlNet-to-DeviceNet Linking Device 31Publication 1788-IN052D-EN-P - February 200775 Either or both of the following:• The device does not have

Seite 26 - DeviceNet Network Status

32 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200778 Device is configured in scan list, but not communicating.

Seite 27 - DNet Network Status Indicator

ControlNet-to-DeviceNet Linking Device 33Publication 1788-IN052D-EN-P - February 200780 Scanner is in idle mode. If desired, put network in run mo

Seite 28 - DNet I/O Status Indicator

34 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200783 Device returns error responses when the scanner attempts t

Seite 29

ControlNet-to-DeviceNet Linking Device 35Publication 1788-IN052D-EN-P - February 200786 The device is in idle mode, or not producing data, while t

Seite 30 - DeviceNet Status Codes

36 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 200791 Bus-off condition likely due to cable or signal errors.• C

Seite 31

ControlNet-to-DeviceNet Linking Device 37Publication 1788-IN052D-EN-P - February 2007View and Interpret Controller Status TagsUse the following pr

Seite 32

38 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20073. Determine which tags you need to view using the following

Seite 33

ControlNet-to-DeviceNet Linking Device 39Publication 1788-IN052D-EN-P - February 20074. Scroll through the list of tags to locate the specific tag

Seite 34

4 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007European Hazardous Location ApprovalEuropean Zone 2 Certificat

Seite 35

40 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20071788-CN2DN Tag Title ExampleTag Titled As_You_Name:I:StausReg

Seite 36

ControlNet-to-DeviceNet Linking Device 41Publication 1788-IN052D-EN-P - February 20075. If need to troubleshoot Status Register tags, use the foll

Seite 37

42 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 20076. If you need to troubleshoot Status Tags (:S), use the foll

Seite 38

ControlNet-to-DeviceNet Linking Device 43Publication 1788-IN052D-EN-P - February 2007Indication that a device is idle.Use the following informatio

Seite 39 - 1756-DNB Tag Title Example

44 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Address with an error.Use the following information to interp

Seite 40 - 788-CN2DN Tag Title Example

ControlNet-to-DeviceNet Linking Device 45Publication 1788-IN052D-EN-P - February 20077. If you need to troubleshoot the CommandRegister tags, use

Seite 41 - Status Register Tag Values

46 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Troubleshoot the ControlNet NetworkIf ControlNet network comm

Seite 42

ControlNet-to-DeviceNet Linking Device 47Publication 1788-IN052D-EN-P - February 2007SpecificationsCN2DN Linking Device, 1788-CN2DNAttribute Value

Seite 43

48 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Environmental SpecificationsAttribute ValueConducted RF Immun

Seite 44

ControlNet-to-DeviceNet Linking Device 49Publication 1788-IN052D-EN-P - February 2007Temperature, Operating IEC 60068-2-1 (Test Ad, Operating Cold

Seite 45

ControlNet-to-DeviceNet Linking Device 5Publication 1788-IN052D-EN-P - February 2007Environment and EnclosureATTENTIONThis equipment is intended f

Seite 46

50 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007CertificationsThe following certifications apply when the pro

Seite 47 - Specifications

ControlNet-to-DeviceNet Linking Device 51Publication 1788-IN052D-EN-P - February 2007Additional ResourcesUse the following table to determine whic

Seite 48 - Environmental Specifications

Publication 1788-IN052D-EN-P - February 2007 PN 953014-33Supersedes Publication 1788-IN052C-EN-P - May 2001 Copyright © 2007 Rockwell Automation, Inc.

Seite 49

6 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Prevent Electrostatic DischargeATTENTIONThis equipment is sens

Seite 50 - Certifications

ControlNet-to-DeviceNet Linking Device 7Publication 1788-IN052D-EN-P - February 2007About the CN2DN Linking DeviceUse following graphic to identif

Seite 51 - Additional Resources

8 ControlNet-to-DeviceNet Linking Device Publication 1788-IN052D-EN-P - February 2007Two ControlNet connection ports are located on the bottom left

Seite 52 - Rockwell Automation Support

ControlNet-to-DeviceNet Linking Device 9Publication 1788-IN052D-EN-P - February 2007Required System ComponentsIn order to install your 1788-CN2DN

Kommentare zu diesen Handbüchern