Rockwell-automation 1775-KA PLC-3 Communication Adapter Module User Ma Bedienungsanleitung Seite 205

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 239
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 204
Remote Error Codes Received from the
1773-KA Module
Appendix B
B13
Error
Error
Code Type Meaning
4.First word of destination location does not exist.
237 reply
For all PLC-3 read and write commands:
1.Any word in the total transaction does not exist in
the destination file.
2.The source and destination files are not the same
size.
238 reply
For all PLC-3 read and write commands:
The file size decreased between packets of a
multi-packet transaction and became too small for
the total transaction.
239 reply
For all PLC-3 read and write commands:
File is larger than 65,535 words.
240 reply
For all PLC-3 read and write commands:
Sum of total transaction size and the word
241 reply
For all PLC-3 write commands:
Remote station does not have access to the
destination file.
Seitenansicht 204
1 2 ... 200 201 202 203 204 205 206 207 208 209 210 ... 238 239

Kommentare zu diesen Handbüchern

Keine Kommentare