Installation Instructions
Compact High-density Analog Current Input
Module
Catalog Number 1769-IF16C
Topic Page
Important User Information 2
Electrostatic Discharge 3
Remove Power 3
Hazardous Location 4
Environnements dangereux 4
About the 1769-IF16C Module 5
Install the 1769-IF16C Module 6
Adding the Module to the 1769 System 6
Mounting Expansion I/O 9
Making Field Wiring Connections 11
Configure the 1769-IF16C Module 15
Specifications 23
Replacement Parts 25
Additional Resources 26
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Catalog Number 1769-IF16C

Installation InstructionsCompact High-density Analog Current Input ModuleCatalog Number 1769-IF16CTopic PageImportant User Information 2Electrostatic

Seite 2 - Important User Information

10 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Use the Dimensional Template Locate holes every 17.5

Seite 3 - Remove Power

Compact High-density Analog Current Input Module 11Publication 1769-IN085A-EN-P - August 2008Mount the Module to a DIN RailThe module can be mount

Seite 4 - Environnements dangereux

12 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008System Wiring GuidelinesConsider the following when w

Seite 5 - About the 1769-IF16C Module

Compact High-density Analog Current Input Module 13Publication 1769-IN085A-EN-P - August 2008Wire Input Sensors/TransmittersLabel the TerminalsA r

Seite 6 - Install the 1769-IF16C Module

14 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Wire the Finger-safe Terminal BlockWhen wiring the te

Seite 7 - Assemble the 1769 System

Compact High-density Analog Current Input Module 15Publication 1769-IN085A-EN-P - August 2008Configure the 1769-IF16C ModuleUse the following I/O

Seite 8 - IMPORTANT

16 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Input Data FileFor each module, slot x, words 0…15 in

Seite 9 - Mounting Expansion I/O

Compact High-density Analog Current Input Module 17Publication 1769-IN085A-EN-P - August 2008The bits are defined as follows:• SGN = Sign bit in 2

Seite 10 - Use Modules as a Template

18 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Word 14 EC Reserved EA ALEI(1)Reserved Input Filter S

Seite 11 - Grounding the Module

Compact High-density Analog Current Input Module 19Publication 1769-IN085A-EN-P - August 2008Word 38 EC Reserved EA ALEI(1)Reserved Input Filter S

Seite 12 - System Wiring Guidelines

2 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Important User InformationSolid state equipment has op

Seite 13 - Label the Terminals

20 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Word 62 EC Reserved EA ALEI(1)Reserved Input Filter S

Seite 14

Compact High-density Analog Current Input Module 21Publication 1769-IN085A-EN-P - August 2008The bits are defined as follows:• SGN = Sign bit in 2

Seite 15 - Output Data File

22 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Bit Definitions for Channel Configuration WordsDefine

Seite 16 - Input Data File

Compact High-density Analog Current Input Module 23Publication 1769-IN085A-EN-P - August 2008SpecificationsCompact High Density Analog Current Inp

Seite 17 - Configuration Data File

24 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Input SpecificationsAttribute ValueAnalog normal oper

Seite 18 - Configuration Data Array

Compact High-density Analog Current Input Module 25Publication 1769-IN085A-EN-P - August 2008Replacement PartsThe module has the following replace

Seite 19

26 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Additional ResourcesFor more information refer to the

Seite 20

Compact High-density Analog Current Input Module 27Publication 1769-IN085A-EN-P - August 2008Notes:

Seite 21

Publication 1769-IN085A-EN-P - August 2008 PN-28831Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.™PN-2•x?R¨Alle

Seite 22

Compact High-density Analog Current Input Module 3Publication 1769-IN085A-EN-P - August 2008Electrostatic DischargeRemove PowerATTENTIONElectrosta

Seite 23 - Specifications

4 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Hazardous LocationThis equipment is suitable for use i

Seite 24 - Input Specifications

Compact High-density Analog Current Input Module 5Publication 1769-IN085A-EN-P - August 2008About the 1769-IF16C ModuleCompact I/O is suitable for

Seite 25 - Replacement Parts

6 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 2008Simplified Input Circuit DiagramInstall the 1769-IF16C

Seite 26 - Additional Resources

Compact High-density Analog Current Input Module 7Publication 1769-IN085A-EN-P - August 2008Assemble the 1769 SystemThe following procedure shows

Seite 27

8 Compact High-density Analog Current Input ModulePublication 1769-IN085A-EN-P - August 20088. Lock the end-cap bus terminator (6). Replace a Sing

Seite 28 - ™PN-2•x?R¨

Compact High-density Analog Current Input Module 9Publication 1769-IN085A-EN-P - August 2008Mounting Expansion I/OMinimum SpacingMaintain spacing

Kommentare zu diesen Handbüchern

Keine Kommentare