Solid-State Output Module 9
Publication 1762-IN007B-EN-P- June 2013
Wiring the Finger-Safe Terminal Block
When wiring the terminal block, keep the finger-safe cover in place.
1. Route the wire under the terminal pressure plate. You can use the stripped end of the wire or a
spade lug. The terminals will accept a 6.35 mm (0.25 in.) spade lug.
2. Tighten the terminal screw making sure the pressure plate secures the wire.
Recommended torque when tightening terminal screws is 0.90 Nm (8 lb-in.).
Wire Size and Terminal Screw Torque
Each terminal accepts up to two wires with the following restrictions:
Finger-safe cover not shown for clarity.
If you need to remove the finger-safe cover, insert a screw driver into one of
the square wiring holes and gently pry the cover off. If you wire the
terminal block with the finger-safe cover removed, you will not be able to
put it back on the terminal block because the wires will be in the way.
Wire Type Wire Size Terminal Screw Torque
Solid Cu-90 °C (194 °F) #14…22 AWG 0.904 Nm (8 lb-in.)
Stranded Cu-90 °C (194 °F) #16…22 AWG 0.904 Nm (8 lb-in.)