Publication 1738-IN012B-EN-E - August 2013
ArmorPOINT I/O 5V DC Encoder/Counter Module, Series A 7
Wire the
Encoder/Counter Module
Following are wiring instructions for the ArmorPOINT Encoder/Counter
module.
1738-IJM23
IMPORTANT
If shielded cable is used, shield lead can be
connected to chassis pin 7, 8, or 12 on the connector.
ATTENTION
Make sure all connectors and caps are securely
tightened to properly seal the connections against
leaks and maintain IP67 requirements.
43681
1738-IJM23
(view into connector)
Pin 1 - +A
Pin 2 - ~A
Pin 3 - +B
Pin 4 - ~B
Pin 5 - +Z
Pin 6 - ~Z
Pin 7 - Chassis
Pin 8 - Chassis
Pin 9 - Return (Com)
Pin 10 - Return (Com)
Pin 11 - 5V DC
Pin 12 - Chassis
Seitenansicht 6