Par # Parameter Name
Factory Default Programmed Value
Par # Parameter Name
Factory Default Programmed Value
1 Output Voltage
Read Only
292 Load Loss Time
0 Sec
2 % Output Curr
Read Only
293 PI Max Error
Maximum Freq Forward
3 % Output Power
Read Only
294 DSP Comm Errors
4 Last Fault
Read Only
295 Max PWM Depth
5 Freq Select 1
Adapter 1
296 Tuned Flux Amps
6 Freq Select 2
Preset 1
297 Tuned IR Drop
7 Accel Time 1
10.0 Sec
298 Run Time Lower
8 Decel Time 1
10.0 Sec
299 Run Time Upper
9 Control Select
Sens Vector
300 Spare
10 Stop Select 1
Coast
301 DSP Code Rev
11 Bus Limit En
Disabled
302 Main Boot Rev
12 DC Hold Time
0.0 Sec
303 Current Lmt En
Enabled
13 DC Hold Level
0%
304 Traverse Dec
0.00 Sec
14 Run On Power Up
Disabled
305 Traverse Mask
01111111
15 Reset/Run Time
1.0 Sec
306 Traverse Owner
Read Only
16 Minimum Freq
0 Hz
307 Sync Time
0.0 Sec
17 Base Frequency
60 Hz
308 Sync Mask
01111111
18 Base Voltage
Drive Rated Volts
309 Sync Owner
Read Only
19 Maximum Freq
60 Hz
310 Sync Loss Sel
Disabled
20 Maximum Voltage
Drive Rated Volts
311 Sync Loss Gain
0
21 Spare 312 Sync Loss Time
5 Sec
22 MOP Increment
1.1 Hz/Sec
313 Sync Loss Comp
0 Volts
23 Output Power
Read Only
314 Braking Chopper
Disabled
24 Jog Frequency
10.0 Hz
315
Alt Type 2 Cmd Disabled
25 Anlg Out 0 Sel
Frequency
316
Application Sts
26 Stop Mode Used
Coast
317
Run/Accel Volts 100%
27 Preset Freq 1
0.0 Hz
318
Max Overflux
28 Preset Freq 2
0.0 Hz
319
Speed Brake En Disabled
29 Preset Freq 3
0.0 Hz
320 Line Loss Volts
59/117/146 Volts
30 Accel Time 2
10.0 Sec
321 Loss Recover
29/59/73 Volts
31 Decel Time 2
10.0 Sec
322 Ride Thru Volts
29/59/73 Volts
32 Skip Freq 1
400 Hz
323 Min Bus Volts
194/388/485 Volts
33 Skip Freq 2
400 Hz
324
Stability Gain 0
34 Skip Freq 3
400 Hz 325 Max Bus Volts 358/716/895 Volts
35 Skip Freq Band
0 Hz
326
Remote CR Output xxxx0000
36 Current Limit
150%
327
At Time 0.00 Sec
37 Overload Mode
No Derate
328
Max Enc Counts 0
38 Overload Amps
115% of Drive Rating
329
Bidir In Offset 270
39 Flt Clear Mode
Enabled
330
Phase Loss Mode Disabled
40 Line Loss Fault
Disabled
331
Phase Loss Level 9.0/18.0/22.5 Volts
41 Motor Type
Induction
332
Precharge Fault Disabled
42 Slip @ F.L.A.
1.0 Hz
43 Dwell Frequency
0.0 Hz
44 Dwell Time
0 Sec
45 PWM Frequency
2 KHz
46 Encoder PPR
1024 PPR
47 Language
English
48 Start Boost
0 Volts
49 Break Frequency
25% of [Maximum Freq]
50 Break Voltage
25% of Drive Rated Voltage
51 Clear Fault
Ready
52 Stop Select 2
Coast
53 DC Bus Voltage
Read Only
54 Output Current
Read Only
55 Input Status
56 S Curve Time
0.0 Sec
57 S Curve Enable
Disabled
58 Common Bus
Disabled