D-2 Logic Command/Status Words
Logic Status Word
1336 PLUS II, 1336 PLUS, and 1305 Drives (Continued)
Logic Bits
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Status Description
x Enabled 0 = Not Enabled
1 = Enabled
x Running 0 = Not Running
1 = Running
x Command
Direction
0 = Reverse
1 = Forward
xActual
Direction
0 = Reverse
1 = Forward
x Accel 0 = Not Accelerating
1 = Accelerating
x Decel 0 = Not Decelerating
1 = Decelerating
x Alarm 0 = No Alarm
1 = Alarm
x Fault 0 = No Fault
1 = Fault
x At Speed 0 = Not At Reference
1 = At Reference
x x x Local Control 000 = TB3
001 = Port 1
010 = Port 2
011 = Port 3
100 = Port 4
101 = Port 5
110 = Port 6
111 = Unused
xxxx Reference 0000 = Freq Select 1
0001 = Preset Freq 1
0010 = Preset Freq 2
0011 = Preset Freq 3
0100 = Preset Freq 4
0101 = Preset Freq 5
0110 = Preset Freq 6
0111 = Preset Freq 7
1000 = Freq Select 2
1001 = Adapter 1
1010 = Adapter 2
1011 = Adapter 3
1100 = Adapter 4
1101 = Adapter 5
1110 = Adapter 6
1111 = Jog Frequency